Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.498
Filtrar
1.
N Z Med J ; 137(1593): 75-80, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38603789

RESUMO

The advent of transcatheter aortic valve implantation (TAVI) has caused a paradigm shift in the management of aortic stenosis away from traditional surgical aortic valve replacement (SAVR). However, uncertainty remains about the long-term (>10 year) durability of TAVI valves, especially in younger patients. This viewpoint collates life expectancy data from Australia and Aotearoa New Zealand to propose sex-specific age-based recommendations for choice of SAVR versus TAVI in their respective general populations and among Aboriginal and Torres Strait Islander people in Australia and both Maori and Pacific peoples living in Aotearoa New Zealand.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Austrália , Expectativa de Vida , Povo Maori , Nova Zelândia , Fatores de Risco , Resultado do Tratamento , Povos Aborígenes Australianos e Ilhéus do Estreito de Torres
3.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616249

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Assuntos
Insuficiência da Valva Aórtica , Parada Cardíaca , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Remoção de Dispositivo
4.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589959

RESUMO

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Assuntos
Bioprótese , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Micoses , Masculino , Humanos , Adulto Jovem , Adulto , Valva Aórtica/cirurgia , Aorta Torácica/cirurgia , Aorta/cirurgia , Endocardite/diagnóstico , Endocardite/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Bioprótese/efeitos adversos
5.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594705

RESUMO

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Valva Aórtica/cirurgia , Resultado do Tratamento
6.
Braz J Cardiovasc Surg ; 39(3): e20230108, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569069

RESUMO

INTRODUCTION: This study aimed to compare the early postoperative outcomes of right anterior thoracotomy minimally invasive aortic valve replacement (RAT-MIAVR) surgery with those of median full sternotomy aortic valve replacement (MFS-AVR) approach with the goal of identifying potential benefits or drawbacks of each technique. METHODS: This retrospective, observational, cohort study included 476 patients who underwent RAT-MIAVR or MFS-AVR in our hospital from January 2015 to January 2023. Of these, 107 patients (22.5%) underwent RAT-MIAVR, and 369 patients (77.5%) underwent MFS-AVR. Propensity score matching was used to minimize selection bias, resulting in 95 patients per group for analysis. RESULTS: After propensity matching, two groups were comparable in preoperative characteristics. RAT-MIAVR group showed longer cardiopulmonary bypass time (130.24 ± 31.15 vs. 117.75 ± 36.29 minutes, P=0.012), aortic cross-clamping time (76.44 ± 18.00 vs. 68.49 ± 19.64 minutes, P=0.004), and longer operative time than MFS-AVR group (358.47 ± 67.11 minutes vs. 322.42 ± 63.84 minutes, P=0.000). RAT-MIAVR was associated with decreased hospitalization time after surgery, lower postoperative blood loss and drainage fluid, a reduced incidence of mediastinitis, increased left ventricular ejection fraction, and lower pacemaker use compared to MFS-AVR. However, there was no significant difference in the incidence of major complications and in-hospital mortality between the two groups. CONCLUSION: RAT-MIAVR is a feasible and safe alternative procedure to MFS-AVR, with comparable in-hospital mortality and early follow-up. This minimally invasive approach may be a suitable option for patients requiring isolated aortic valve replacement.


Assuntos
Valva Aórtica , Implante de Prótese de Valva Cardíaca , Humanos , Valva Aórtica/cirurgia , Esternotomia/métodos , Toracotomia/métodos , Estudos Retrospectivos , Estudos de Coortes , Pontuação de Propensão , Volume Sistólico , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Tempo de Internação , Função Ventricular Esquerda
8.
Catheter Cardiovasc Interv ; 103(5): 766-770, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38564317

RESUMO

BACKGROUND: Cardiac damage has gained increasing attention as a valid prognostic marker of mortality after transcatheter aortic valve replacement (TAVR). However, studies investigating the possible association between cardiac damage and hospitalization burden in TAVR patients are lacking. AIMS: This study aimed to investigate the impact of baseline cardiac damage on the hospitalization burden before, during, and after TAVR in an all-comers population. METHODS: All consecutive patients who underwent TAVR between 2016 and 2020 were included. Electronic medical records of all patients were examined to validate cardiovascular (CV) and heart failure (HF) related hospitalizations from 6 months before to 1 year after TAVR. Baseline cardiac damage was defined according to the staging classification by Généreux et al. RESULTS: Among 1397 TAVR patients, 94 (6.7%) had stage 0, 368 (26.4%) stage 1, 736 (52.7%) stage 2, 115 (8.2%) stage 3, and 84 (6.0%) stage 4 cardiac damage. Patients with more advanced cardiac damage at baseline had more HF hospitalizations within 6 months before TAVR (p < 0.01) and with a longer length of stay (LoS) (p < 0.01). Regarding the index TAVR admission, there was no difference in procedure time (p = 0.26) or LoS (p = 0.18) between groups. Still, TAVR patients with more advanced baseline cardiac damage had a higher risk of CV and HF rehospitalization after TAVR (p < 0.05). CONCLUSIONS: Baseline cardiac damage in patients undergoing TAVR has an impact on the pre- and post-procedural cardiovascular hospitalization burden. However, the cardiac damage status does not affect the TAVR procedure time or index TAVR admission length of stay.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , Hospitalização , Tempo de Internação , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
10.
J Cardiothorac Surg ; 19(1): 258, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643131

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) and left ventricular (LV) dysfunction demonstrate improvement in left ventricular injection fraction (LVEF) after aortic valve replacement (AVR). The timing and magnitude of recovery in patients with very low LVEF (≤ 25%) in surgical or transcatheter AVR is not well studied. OBJECTIVE: Determine clinical outcomes following transcatheter aortic valve replacement (TAVR) and surgical aortic valve repair (SAVR) in the subset of patients with severely reduced EF ≤ 25%. METHODS: Single-center, retrospective study with primary endpoint of LVEF 1-week following either procedure. Secondary outcomes included 30-day mortality and delayed postprocedural LVEF. T-test was used to compare variables and linear regression was used to adjust differences among baseline variables. RESULTS: 83 patients were enrolled (TAVR = 56 and SAVR = 27). TAVR patients were older at the time of procedure (TAVR 77.29 ± 8.69 vs. SAVR 65.41 ± 10.05, p < 0.001). One week post procedure, all patients had improved LVEF after both procedures (p < 0.001). There was no significant difference in LVEF between either group (TAVR 33.5 ± 11.77 vs. SAVR 35.3 ± 13.57, p = 0.60). Average LVEF continued to rise and increased by 101% at final follow-up (41.26 ± 13.70). 30-day mortality rates in SAVR and TAVR were similar (7.4% vs. 7.1%, p = 0.91). CONCLUSION: Patients with severe AS and LVEF ≤ 25% have a significant recovery in post-procedural EF following AVR regardless of method. LVEF doubled at two years post-procedure. There was no significant difference in 30-day mortality or mean EF recovery between TAVR and SAVR. TRIAL REGISTRATION: Indiana University institutional review board granted approval for above study numbered 15,322.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Fatores de Risco
11.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629416

RESUMO

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Ventrículos do Coração , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Clínicos como Assunto
12.
JAMA Netw Open ; 7(4): e247525, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639933

RESUMO

Importance: Aggregated data and long-term follow-up in national health data registers offer the opportunity to compare the performance of mechanical aortic prostheses within the same population. Objective: To investigate the clinical performance of mechanical aortic valve prostheses. Design, Setting, and Participants: This nationwide cohort study included all 5224 patients who underwent primary mechanical aortic valve replacement in Sweden between January 1, 2003, and December 31, 2018. Statistical analysis was performed between May and September 2023. Exposures: Surgical aortic valve replacement with the On-X, Carbomedics, Bicarbon, Standard, Regent, Open Pivot, Masters, or Advantage valve models. Main Outcomes and Measures: The primary outcome was all-cause mortality, and secondary outcomes were reintervention, heart failure, major bleeding, stroke, and embolic events. Regression standardization was used to account for baseline differences. Results: Overall, 5224 patients (mean [SD] age, 56.8 [11.7] years; 3908 men [74.8%]) were included. Total follow-up time was 43 982 person-years (mean [SD], 8.4 [4.6] years; maximum, 17.2 years). After regression standardization, there was a significant difference in 10-year mortality between the Carbomedics model group (17%; 95% CI, 15%-18%), Regent model group (17%; 95% CI, 13%-20%), and Standard model group (17%; 95% CI, 14%-19%) compared with the Bicarbon model group (27%; 95% CI, 21%-34%). Conclusions and Relevance: In this cohort study of mechanical valve surgical aortic replacement outcomes in Sweden, the rate of all-cause mortality was higher in the Bicarbon group than in the Carbomedics, Regent, and Standard model groups. These findings warrant further research on the long-term clinical performance of the Bicarbon valve.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Estudos de Coortes , Desenho de Prótese
14.
J Cardiothorac Surg ; 19(1): 237, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627730

RESUMO

Redo ascending and aortic arch surgeries following previous cardiac or aortic surgery are associated with high risk of morbidity and mortality due to multiple factors included sternal re-entry injury, extensive aortic arch surgery, emergency aortic surgery, prolonged cardiopulmonary bypass duration, poor heart function, and patients with older age. Therefore, appropriate surgical strategies are important. We report a case of a 72-year-old gentleman with previous surgery of aortic root replacement who presented with acute Type A aortic dissecting aneurysm of ascending and aortic arch complicated with left hemothorax, which was successfully treated by emergency redo aortic surgery with frozen elephant trunk (FET) technique.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Masculino , Humanos , Idoso , Aorta Torácica/cirurgia , Prótese Vascular , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Valva Aórtica/cirurgia , Dissecção Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Stents
15.
J Cardiothorac Surg ; 19(1): 220, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627803

RESUMO

BACKGROUND: Splenic abscess is a serious complication associated with infective endocarditis. There is still contradicting evidence regarding the optimal treatment pathway including timing of valve intervention and the approach for managing splenic foci. CASE PRESENTATION: We present a case of a hybrid staged approach in which we successfully performed a laparoscopic splenectomy following percutaneous abscess drainage and a delayed aortic valve replacement. CONCLUSIONS: A multidisciplinary teamwork is fundamental in providing optimal care for patients with distant complications associated with infective endocarditis. Our hybrid approach seems safe and feasible.


Assuntos
Embolia , Endocardite Bacteriana , Endocardite , Esplenopatias , Humanos , Esplenopatias/cirurgia , Esplenopatias/complicações , Abscesso/etiologia , Abscesso/cirurgia , Valva Aórtica/cirurgia , Endocardite/complicações , Endocardite/cirurgia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/cirurgia , Embolia/complicações
16.
J Cardiothorac Surg ; 19(1): 236, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627814

RESUMO

BACKGROUND: Infective endocarditis of the aortic valve can result in a wide range of destructive pathology beyond the valve leaflets and annulus which require careful surgical planning to provide appropriate debridement and reconstruction. Failure to do so can result in a failure of surgical treatment, recurrent infection and cardiac failure with concomitant high morbidity and mortality. CASE REPORT: We describe the case of a 45-year-old male with previous patch repair of a ventricular septal defect, who was diagnosed with sub-acute bacterial endocarditis of the native aortic valve and developed a new fistula from the aorta to the right ventricular outflow tract which. This was managed surgically. CONCLUSION: This unique case highlights another spectrum of infective endocarditis with a unique approach to repair and management.


Assuntos
Endocardite Bacteriana , Endocardite , Comunicação Interventricular , Doenças das Valvas Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Endocardite Bacteriana/complicações , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/diagnóstico , Endocardite/complicações , Comunicação Interventricular/cirurgia , Comunicação Interventricular/complicações , Valva Aórtica/cirurgia , Aorta
17.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627820

RESUMO

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Humanos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Bioprótese/efeitos adversos , Desenho de Prótese , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Fatores de Risco , Progressão da Doença
19.
BMC Cardiovasc Disord ; 24(1): 195, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580959

RESUMO

OBJECTIVES: Using the cardiac surgery database is of high importance in referral centers and can lead to a better quality of care for patients. Tehran Heart Center (THC) is a cardiovascular referral center that was inaugurated in 2001. In this report, we aimed to present the third report of trends in patients' cardiovascular risk factors and surgical procedures from 2002 to 2021 that have been gathered for all THC patients. METHODS: This serial cross-sectional study was conducted at Tehran Heart Center from 2002 to 2021. All patients undergoing cardiac surgeries were eligible to enter the study (N = 63,974). Those with miscellaneous types of surgeries were excluded (N = 9556). The distribution of cardiac surgeries (including isolated coronary artery bypass graft (CABG), isolated valve, and CABG + valve surgeries) and their respective in-hospital mortality were recorded. Furthermore, 20-year trends in the prevalence of various cardiovascular risk factors (CVRFs) among the following groups were evaluated: a) isolated CABG, b) aortic valve replacement/repair for aortic stenosis (AS/AVR/r), and c) isolated other valve surgeries (IVS). RESULTS: A total of 54,418 patients (male: 70.7%, age: 62.7 ± 10.8 years) comprised the final study population, with 84.5% prevalence of isolated CABG. Overall, the AS/AVR/r group was in between the CABG and IVS groups concerning CVRFs distribution. Excluding some exceptions for the AS/AVR/r group (in which the small sample size (N = 909) precluded observing a clear trend), all studied CVRFs demonstrated an overall rising trend from 2002 to 2021 in all three groups. Regarding in-hospital mortality, the highest rate was recorded as 4.0% in 2020, while the lowest rate was 2.0% in 2001. CONCLUSIONS: Isolated CABG remained the most frequent procedure in THC. Notable, increasing trends in CVRFs were observed during this 20-year period and across various types of cardiac surgeries, which highlights the clinical and policy-making implications of our findings.


Assuntos
Estenose da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Estudos Transversais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Irã (Geográfico)/epidemiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
20.
J Cardiothorac Surg ; 19(1): 196, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600556

RESUMO

BACKGROUND: The transcarotid (TC) vascular access for transcatheter aortic valve implantation (TAVI) has emerged as the first-choice alternative to the transfemoral access, in patients unsuitable for the latter. The use of both the left and right common carotid arteries (CCAs) for TC-TAVI has been described, but the optimal side is subject to debate. We conducted this pilot study to compare the level of vessel tortuosity and plaque burden from either the left CCA to the aortic annulus, or the right CCA to the aortic annulus, considering them as surrogates for technical and procedural complexity. METHODS: Consecutive patients who underwent TC-TAVI between 2018 and 2021 in our institution were included. Using three-dimensional reconstruction, pre-TAVI neck and chest computed tomography angiography exams were reviewed to assess the tortuosity index (TI), sum of angles metric, as well as plaque burden, between each CCA and the aortic annulus. RESULTS: We included 46 patients who underwent TC-TAVI. No significant difference regarding the mean TIs between the left and right sides (respectively 1.20 and 1.19, p = 0.82), the mean sum of angles (left side: 396°, right side: 384°, p = 0.27), and arterial plaque burden (arterial plaque found in 30% of left CCAs and 45% of right CCAs, p = 0.19) was found. CONCLUSIONS: We found no convincing data favoring the use of one particular access side over the other one. The choice of the CCA side in TC-TAVI should to be made on a case-by-case basis, in a multidisciplinary fashion, and may also depend on the operators' experience.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Projetos Piloto , Artéria Carótida Primitiva/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...